Gables Building
Inspections
★★★★★ 4.8 on Google · 570+ reviews

Lock-up inspection in Gables

Services, flashings and gutters, seen before the plasterboard closes the walls.

  • Roof, cladding, windows and rough-in done, before plaster
  • 1 to 2 hours on site
  • Report within 24 hours
Request your quoteLeave your details and an inspector rings you back.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

Stage4 of 7
When to bookRoof, cladding, windows and rough-in done, before plaster
Time on site1 to 2 hours on site
Inspected againstAS 3700 (masonry), AS 4773, AS 2047 (windows), NCC Part 3.5 roof and wall cladding, manufacturer flashing details

What is included in a Gables lock-up (pre-plaster) inspection

  • Cables kept 25mm from hot and cold water pipes
  • Gas lines separated from water pipes
  • Pipes separated from steel framing
  • Flexible ducts hung, not resting
  • Head flashings past each side of openings
  • Box gutters sized for their roof area
  • Box gutters falling to outlets
  • Sarking and wall wrap without tears
  • Damp proof course clear of debris
  • Brickwork bearing on the slab edge
  • Roof penetrations flashed
  • Earlier frame items rechecked
  • Weep holes formed
Why it matters here

Lock-up (pre-plaster) inspections on Gables builds

The Gables lock-up list is led by services. Electrical cables pressed against hot and cold water pipes inside the 25mm separation. Gas pipes and water pipes touching steel framing with nothing between them. Ducts lying on the ceiling frame. On the outside we have recorded head flashings stopping short of the opening, a box gutter too shallow for its roof and another holding water.

What we find at this stage in Gables

  • Cables touching hot and cold water pipes
  • Gas and water pipes against steel
  • Ducts not suspended
  • Head flashings too short
  • Box gutter undersized or holding water
Air conditioning ducting not suspended, so it sags and strains its joints, found during a lock-up inspection in Gables
Air conditioning ducting not suspended, so it sags and strains its joints
Sample findings

Sample defects found during our lock-up (pre-plaster) inspections in Gables

Annotated findings from Lock-up (pre-plaster) inspections.

Electrical cables against hot water pipework, inside the 25mm separation required, found during a lock-up inspection in Gables
Electrical cables against hot water pipework, inside the 25mm separation required
Water pipes resting on metal framing without a divider between them, found during a lock-up inspection in Gables
Water pipes resting on metal framing without a divider between them
Window head flashing stopping short of the 150mm it should run past each side, found during a lock-up inspection in Gables
Window head flashing stopping short of the 150mm it should run past each side
Front box gutter too shallow for the roof area draining into it, found during a lock-up inspection in Gables
Front box gutter too shallow for the roof area draining into it

The other stages of a Gables build

  1. Bored piers inspection in Gables1Bored piersOnce the piers are bored, before any concrete arrives
  2. Slab pre-pour inspection in Gables2Slab pre-pourThe day before the pour, once steel and pods are set
  3. Frame inspection in Gables3FrameFrame and trusses standing, roof cover on, before sarking and linings
  4. Fixing inspection in Gables5FixingJoinery, doors and trims in, before the painter starts
  5. Waterproofing inspection in Gables6WaterproofingMembrane cured, before the tiler arrives
  6. Pre-handover (PCI) inspection in Gables7Pre-handover (PCI)About two weeks before your handover date

All construction stage inspections in Gables →

Guides

Construction stage guides for Gables

All guides →

Book a lock-up (pre-plaster) inspection in Gables

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Lock-up (pre-plaster) inspections in Gables: common questions

Why does a 25mm gap matter?

Heat and contact wear cable insulation, and dissimilar metals react. Keeping services apart is a requirement, and it can only be seen before the walls are lined.

Is this an electrical inspection?

No. We record physical clearances we can see. The wiring itself is certified by a licensed electrician.

How long will a Gables lock-up visit run?

Allow one to two hours, more on a double storey.

What happens to the frame items from before?

We check each one again and mark it fixed or still open.

Why look at box gutters now?

Their size and fall are easy to change at this stage and hard once ceilings are in.

Does the builder fix services items quickly?

Usually yes, because the trades are still on site and the fix is a clip or a spacer.

CallGet a Free Quote